Description: Uniden Bearcat BCD996XT Digital Trunktracker IV Mobile / Base Scanner. Condition: Used. Great condition. Light signs of use, not abused. Tested fully functional. Cleared out to factory original settings. Local city or town recently switch to digital, this is the unit you need. Picks up all analog and P25 digital phase 1. Includes: -Qty 1 Uniden BCD996XT Scanner -Qty 1 AC power adapter -Qty 1 Antenna -Qty 1 Owners manual and programming software (on disk) No bracket, no programming cable or any other accessories included. Everything included as shown in pictures. Bid with confidence. 20+ year ebay member. ---------------------------------------------------------------------------------------------------------------------------------------------------- UNIDEN BCD996XT DIGITAL SCANNER Specifications for reference only PhysicalAntenna Connector: BNCCompatible with BC-RH96 Remote HeadDIN-E and ISO Vehicle Mountable sleeve includedGPS Support for Location Based Scanning, location alerts, and crows-flight navigationLCD and Keypad BacklightMulti-color display backlightPC Programming and ControlRecord Out - you can connect an output jack to a VOX controlled recorder or PC sound input to record the received audio.Reversible Display - Lets you reverse the display to mount unit upside down (and hear the speaker from the top)Signal Strength displayStrong signal attenuation16 character text tagging for each system, site, group, channel, talkgroup, search range, location, Tone-out, and SAME group12 Service Searches - Public Safety, News, HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, FM Broadcast, Military Air, and Special (Itinerant) KeysGroup Quick Key range: 0-9Startup Keys: 10System Quick Key range: 0-993 Quick Access Search Keys TechnicalBand Scope Span Range: 0.2 Mhz To 500 MhzBand Scope Step: 5 Khz To 100 KhzChannels: 25,000 maximumChannel Number Tagging: 999Channels per conventional system: 1000 maximumCustom Search Ranges: 10Groups per system: 20 maximum3 (vs. 6) Quick-Access Search KeysPreprogrammed Service Search Bands: 12Scan Rate: 100 channels per second (conventional mode)Search Rate: 300 steps per second (on 5 kHz steps)Supported step sizes: 5, 6.25, 7.5, 8.33, 10, 12.5,15, 20, 25, 50 or 100 kHzSystem Number Tagging: 999Systems: 500 maximumTalkgroups per trunked system: 500 maximum500 (250 Temporary + 250 Permanent) Search Lockouts Frequency Coverage25.0000 - 512.0000 MHz758.0000 - 823.9875 MHz849.0125 - 868.9875 MHz894.0125 - 960.0000 MHz1240.0000 - 1300.0000 MHz FM BandwidthsNFM: ~7.5 kHz deviationFM ~15 kHz deviationFMB: ~75 kHz deviationWFM: >100 kHz deviation Power RequirementsPower requirements: AC Adapter (13.8V DC 750mA Regulated) (AD-1009 or equivalent).DC:11V to 16.6V(Ext.DC Power Jack or DC Power Jack)Power plug: 5.5mm outer diameter, 2.1mm inner diameter FeaturesAbility to flag a channel as Digital, Analog, or AllAdaptive Digital Threshold - Automatically sets the digital decode threshold for APCO 25 systemsAdjustable Hold (scan duration 0-255 sec) per system, custom or service searchAnalog and Digital AGCAPCO25 Digital Audio decodingBroadcast Screen while searching (TV and radio station frequencies, pagers, etc) with 10 custom bandsClose Call, with Close Call Do Not Disturb, Close Call Priority (or Primary), and Close Call Temporary Store.Control Channel OnlyCustom Search — lets you program up to 10 search rangesDCS/CTCSS Rapid DecodeDuplicate Channel AlertFire Tone Out alertFrequency/ID AutoStore - automatically store frequencies from a service or limit search into a conventional system or store talk group IDs into a trunked systemIndependent Alert Tone Volume – lets you set the volume level of the following tones: Key Beep, Emergency Alert, Channel Alert, and Close Call Alert.Key LockLocation Based ScanningMulti-Site supportPriority ScanP25 audio decode level adjustmentQuick SearchRepeater ReverseSearch with Scan for Service and Custom Searches with assigned Quick KeysStartup ConfigurationTemporary System, Site, Group, Channel, and Location LockoutUpgradeable firmwareCan be updated to support Rebanding? YESThis scanner supports rebanding with firmware already installed. See the Updating the Firmware in Uniden DMA Scanners article for the firmware link Weather OperationsWired Cloning (Will only Clone to another BCD996XT) Improvements over the BCD996TAdjustable Band defaultsAdjustable Priority check intervalBand Scope modeChannel AlertControl Channel Data OutputDisplay the Unit IDs (UID) found on trunk systems. Firmware 1.04.00 or newer is required.EDACS ESK supportFire Tone Out Search - built-in frequency counter displays the received tones.Individual channel volume offsetIntermediate Frequency Exchange - changes the IF used for a selected frequency to help avoid image and other mixer-product interference on a frequency.Key Lock - lets you hand the scanner to a novice user and prevent programming from being modified.NAC decodingNegative Channel dropout delay (forced resume) adjustable to 0-2,5,10,30, -2, -5, -10 secondsNumber Tags allows you to quickly navigate to a specific Favorites List, System, and/or Channel.Preemptive Priority on Motorola analog systemsPriority ID Scan on trunked systemsPrivate Systems - lets you flag a system so that it cannot be read out of the scanner or modified.P25 Conventional channels that include NAC and TGID user differentiation (P25 One-Frequency Trunk)Startup ConfigurationTemporary System, Site, Group, Channel, and Location Lockout RR System Compatibility This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range: System Types:Motorola Type IMotorola Type IIMotorola Type IIi HybridMotorola Type II SmartnetMotorola Type II SmartZoneMotorola Type II SmartZone OmniLinkMotorola Type II VOCEDACS Standard (Wide)EDACS Standard NetworkedEDACS NarrowbandEDACS Narrowband NetworkedEDACS SCATEDACS ESK (not ProVoice)LTR StandardProject 25 Standard Phase 1 System Voices:AnalogAnalog and APCO-25 Common Air InterfaceAPCO-25 Common Air Interface Exclusive Preloaded Systems and their System Quick Keys Press and hold 2,9, and Hold, power on the scanner to re-initialize the Memory and restore the Preloaded systems. When it asks do you wish to restore the preloaded systems press the E/Yes key. WARNING This will erase any personal programming you may have done to your DMA. The preloaded system list for the BCD996XT: SQKSystem 21Alaska ALMR22Arkansas AWIN23Colorado DTRS24Connecticut State25Delaware26Georgia GEWIN27Idaho IIMARS28Illinois StarCom2129Indiana SAFE-T30Kansas KSICS31Louisiana LATIE32Mass State Sys [Analog]33Michigan MPSCS34Mississippi MWIN35Montana StateSys36NC VIPER37Nevada SRS38Ohio MARCS39Rhode Isl RISCON40SC Palmetto 80041SDakotaState42TX DPS43Utah UCAN44Virginia STARS45WVirginia WVIRP46WyoLink
Price: 300 USD
Location: North Providence, Rhode Island
End Time: 2024-10-11T16:32:35.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Uniden Bearcat
Type: Mobile
Model: BCD996XT
MPN: BCD996XT